ACC (Applied Computer Controls)
CoLd = Temperature in the spa heater housing is below 40° F. Status of the heater element is unknown. The low speed pump or circ pump will operate continuously until the temperature rises above 45° F.
OH = Over heat. The spa is at a temperature above 108° . Do not use spa
when temperature is flashing or the OH message is displayed.
HLoH = Hi Limit Over Heat. Hi limit sensor is disconnected or shorted or the spa temperature is above 112° F.
SEoP = Sensor open or disconnected. Heater disabled but the spa is
operational.
SESH = Sensor short, nonfunctional. Heater disabled but the spa is operational.
PSoC = Pressure switch open with circulating pump.
PSoL = Pressure switch open with low pump.
PSoH = Pressure switch open with high pump.
ToE = Time out error. Rare system error. Spa unusable. Contact ACC.
Brett Aqualine
OH = Temp exceeds 118° F
Fr = Freeze condition – temp below 40° F
FL = Pressure switch failure
EO = Shorted temp sensor
E1 = Open temp sensor
E2 = Shorted hi-limit sensor
E3 = Open hi-limit sensor
E4 = Shorted flow switch
E7 = Improper electrical connection